نتایج جستجو برای: tld dosimetry

تعداد نتایج: 8771  

2012
Juan Azorín Nieto Juan Azorin Nieto

Radiation dosimetry is fundamental in Medical Physics, involving patients and phantom dosimetry. In both cases thennoluminescence dosimetry (TLD) is the most appropriate technique for measuring the absorbed dose. In this paper thennoluminescence phenomenon as well as the use of TLD in radiodiagnosis and radiotherapy for in vivo or in phantom measurements is discussed. Some results of measuremen...

2003
G. Ibbott

Several national and international organizations have developed various types and levels of external audits for radiotherapy dosimetry, either based on on-site review visits or using mailed dosimetry systems. Three major TLD (thermoluminescent dosimetry) networks make available postal dose audits to a large number of radiotherapy centres on a regular basis. These are the IAEA/WHO TLD postal dos...

2014
SM Hosseini Pooya T Orouji

BACKGROUND The accurate results of the individual doses in personal dosimety which are reported by the service providers in personal dosimetry are very important. There are national / international criteria for acceptable dosimetry system performance. Objective : In this research, the sources of uncertainties are identified, measured and calculated in a personal dosimetry system by TLD. METHO...

Journal: :Medical physics 1992
T H Kirby W F Hanson D A Johnston

Thermoluminescence dosimeters (TLD) are widely used to verify absorbed doses delivered from radiation therapy beams. Specifically, they are used by the Radiological Physics Center for mailed dosimetry for verification of therapy machine output. The effects of the random experimental uncertainties of various factors on dose calculations from TLD signals are examined, including: fading, dose resp...

2015
M. Sadeghi S. Sina R. Faghihi

LiF, Mg and Ti cubical TLD chips (known as TLD-100) are widely used for dosimetry purposes. The repeatability of TL dosimetry is investigated by exposing them to doses of (81, 162 and 40.5 mGy) with 662keV photons of Cs-137. A group of 40 cubical TLD chips was randomly selected from a batch and the values of Element Correction Coefficient (ECC) were obtained 4 times by irradiating them to doses...

2008
Maria Inês Teixeira Sonia G. P. Cecatti Linda V. E. Caldas

Cases involving high-doses of ionizing radiation are becoming increasingly common.The objective of this work was to characterize thermoluminescent materials for the dosimetry of workers exposed to high doses. Samples of TLD-200, TLD-400 and TLD-800 pellets from Thermo Electron Corporation were studied in gamma high-doses. Dose-response curves were obtained for doses between 100 mGy and 100 Gy. ...

Journal: :Revista panamericana de salud publica = Pan American journal of public health 2006
Joanna Izewska Stanislav Vatnitsky Kenneth R Shortt

Since 1969 the International Atomic Energy Agency and the World Health Organization (along with the Pan American Health Organization, working with countries in Latin America and the Caribbean) have operated postal dosimetry audits based on thermoluminescent dosimetry (TLD) for radiotherapy centers. The purpose of these audits is to provide an independent dosimetry check of radiation beams used ...

Journal: :Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics 2008
B Hill A J Venning C Baldock

Polymer gel dosimetry undertaken on a multislice CT scanner provides an alternative method to conventional dosimetry measurements. Polymer gel dosimeters were used to measure CT radiation doses and compared to TLD and ionization chamber measurements in different diameter phantoms. CTDI was investigated for each of these phantoms for a range of mAs (100-400 mAs), tube voltage (100-135 kV) and no...

Journal: :Journal of physics. Conference series 2009
Hs Sakhalkar D Sterling J Adamovics G Ibbott M Oldham

An urgent requirement for 3D dosimetry has been recognized because of high failure rate (~25%) in RPC credentialing, which relies on point and 2D dose measurements. Comprehensive 3D dosimetry is likely to resolve more errors and improve IMRT quality assurance. This work presents an investigation of the feasibility of PRESAGE/optical-CT 3D dosimetry in the Radiologic Physics Center (RPC) IMRT H&...

Journal: :Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology 2000
J Izewska P Andreo

BACKGROUND AND PURPOSE Since 1969 the International Atomic Energy Agency (IAEA), together with the World Health Organization (WHO), has performed postal TLD audits to verify the calibration of radiotherapy beams in developing countries. MATERIALS AND METHODS A number of changes have recently been implemented to improve the efficiency of the IAEA/WHO TLD programme. The IAEA has increased the n...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید